Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to
Query
Tx Clock
Invert
TCI=
1 byte, value 0
or 1
Command or Query.
Invert Transmit Data Clock in the form x, where:
0=Normal
1=Inverted
TCI=
TCI?
TCI*
TCI#
TCI?
TCI=x
(see Description of
Arguments)
Tx Audio
Volume
Control
TVL=
4 bytes
Command or Query. (Audio/IDR parameter)
Tx Audio Volume control in the form aabb, where:
aa=Tx 1 volume control in dB, valid values are -6, -4, -2, +0, +2, +4, +6, +8;
bb=Tx 2 volume control in dB, valid values are -6, -4, -2, +0, +2, +4, +6, +8;
Example: TVL= -2+4 (sets Tx 1 to 2 dB and Tx 2 to +4 dB)
TVL=
TVL?
TVL*
TVL#
TVL?
TVL=aabb
(see Description of
Arguments)
Transmit
Terrestrial
Alarm Mask
TTA=
1 byte, 0 or 1 Command or Query. (DROP parameter)
Transmit terrestrial Alarm Mask conditions in the form x, where:
0=Alarm is active (unmasked).
1=Alarm is masked.
Example: TTA=1 (masks an alarm).
TTA=
TTA?
TTA*
TTA#
TTA?
TTA=x
(see Description of
Arguments)
Drop Type
DTY=
1 byte, value
of 0 thru 3
Command or Query. (DROP/D&I++/QDI parameter)
Drop Type in the form x, where:
0=T1–D4
1=T1–ESF
2=E1–CCS
3=E1–CAS
DTY=
DTY?
DTY*
DTY#
DTY?
DTY=x
(see Description of
Arguments)
Tx Drop
Timeslot
DTS=
3 bytes
Command or Query. (Drop parameter)
(Note different format between command and query.)
Command format: DTS=xxy, where:
xx = Channel 01 through 24
y = timeslot: 0-9, A=10, B=11, C=12, D=13,…V=31
DTS=
DTS?
DTS*
DTS#
DTS?
DTS=yyyyyyyyyyyyy
yyyyyyyyyyy
indicating all 24 Drop
timeslots values
associated with the
24 Tx Satellite
channels.
Tx Ternary
Code
TTC=
1 byte, value
of 0 thru 3
Command or Query. (G.703 parameter)
Tx Ternary Code in the form x, where:
0=AMI
1=B8ZS
2=B6ZS
3=HDB3
Example: TTC=1 (selects B8ZS)
TTC=
TTC?
TTC*
TTC#
TTC?
TTC=x
(see Description of
Arguments)
Transmit
Backward
Alarms
Enable
TBA=
4 bytes, each
a value of 0
thru 2
Command or Query. (IDR parameter)
Transmit Backward Alarm enable in the form xxxx, where:
0=Disable
1=Enable Internal (S/W)
2=Enable External (H/W)
Example: TBA=0120
TBA=
TBA?
TBA*
TBA#
TBA?
TBA=xxxx
Position indicates
backward alarm
numbers: 1234