Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to

Query

Tx Clock

Invert

TCI=

1 byte, value 0

or 1

Command or Query.

Invert Transmit Data Clock in the form x, where:

0=Normal

1=Inverted

TCI=

TCI?

TCI*

TCI#

TCI?

TCI=x

(see Description of

Arguments)

Tx Audio

Volume

Control

TVL=

4 bytes

Command or Query. (Audio/IDR parameter)

Tx Audio Volume control in the form aabb, where:

aa=Tx 1 volume control in dB, valid values are -6, -4, -2, +0, +2, +4, +6, +8;

bb=Tx 2 volume control in dB, valid values are -6, -4, -2, +0, +2, +4, +6, +8;

Example: TVL= -2+4 (sets Tx 1 to 2 dB and Tx 2 to +4 dB)

TVL=

TVL?

TVL*

TVL#

TVL?

TVL=aabb

(see Description of

Arguments)

Transmit

Terrestrial

Alarm Mask

TTA=

1 byte, 0 or 1 Command or Query. (DROP parameter)

Transmit terrestrial Alarm Mask conditions in the form x, where:

0=Alarm is active (unmasked).

1=Alarm is masked.

Example: TTA=1 (masks an alarm).

TTA=

TTA?

TTA*

TTA#

TTA?

TTA=x

(see Description of

Arguments)

Drop Type

DTY=

1 byte, value

of 0 thru 3

Command or Query. (DROP/D&I++/QDI parameter)

Drop Type in the form x, where:

0=T1–D4

1=T1–ESF

2=E1–CCS

3=E1–CAS

DTY=

DTY?

DTY*

DTY#

DTY?

DTY=x

(see Description of

Arguments)

Tx Drop

Timeslot

DTS=

3 bytes

Command or Query. (Drop parameter)

(Note different format between command and query.)

Command format: DTS=xxy, where:

xx = Channel 01 through 24

y = timeslot: 0-9, A=10, B=11, C=12, D=13,…V=31

DTS=

DTS?

DTS*

DTS#

DTS?

DTS=yyyyyyyyyyyyy

yyyyyyyyyyy

indicating all 24 Drop

timeslots values

associated with the

24 Tx Satellite

channels.

Tx Ternary

Code

TTC=

1 byte, value

of 0 thru 3

Command or Query. (G.703 parameter)

Tx Ternary Code in the form x, where:

0=AMI

1=B8ZS

2=B6ZS

3=HDB3

Example: TTC=1 (selects B8ZS)

TTC=

TTC?

TTC*

TTC#

TTC?

TTC=x

(see Description of

Arguments)

Transmit

Backward

Alarms

Enable

TBA=

4 bytes, each

a value of 0

thru 2

Command or Query. (IDR parameter)

Transmit Backward Alarm enable in the form xxxx, where:

0=Disable

1=Enable Internal (S/W)

2=Enable External (H/W)

Example: TBA=0120

TBA=

TBA?

TBA*

TBA#

TBA?

TBA=xxxx

Position indicates

backward alarm

numbers: 1234