beautypg.com

6 redundancy page – Comtech EF Data CDM-625 User Manual

Page 270

background image

CDM-625 Advanced Satellite Modem

Revision 15

Ethernet-based Remote Product Management

MN-CDM625

6–78

6.5.4.6 Redundancy page

Take note of the following redundant switch information, as it pertains to IP

Packet Processor Redundancy:

1:1 Redundancy is supported using either a CRS-170A L-Band 1:1

Redundancy Switch or a CRS-180 70/140 MHz 1:1 Redundancy Switch, and

a user-supplied, off-the-shelf Ethernet switch.

1:N Redundancy is supported using a CRS-300 1:10 Redundancy Switch or a

CRS-500 M:N Redundancy System in 1:N mode based on the following

criteria:

Redundancy Device

Packet Processor

Terrestrial Interface

Mode

CRS-300

Disabled

Any

Any

CRS-500

Disabled

EIA-422/530, V.35,

Sync EIA-232

Any

Enabled

Ethernet

L3 or Bridge

Packet Processor Redundancy is supported in both 1:1 and 1:N redundant

configurations using the CRS-500 M:N Redundancy System.

See your pertinent switch Installation and Operation Manuals for detailed

information on using the CDM-625 in a redundancy configuration.

Figure 6-49. Redundancy page

Redundancy Config

Redundancy Traffic IP Address – Enter the IP Address and subnet mask in the form

XXX.XXX.XXX.XXX/YY.