Comtech EF Data CDM-625 User Manual
Page 634

CDM-625 Advanced Satellite Modem
Revision 15
Appendix F
MN-CDM625
F–16
Selection
Setting
Mute
(Mute setting) Muted (i.e., Tx off) or Unmuted (i.e., Tx on)
Slope
Manual (0.0 to 1.0, in increments of 0.1) or Calibrated
Press ENTER to save, or CLEAR to cancel and return to the previous menu.
F.3.3.3.3.1.1.2 ODU: FSK-control CSAT (2CSATs CSAT #X)
Configuration Rx
Rx: Fq=6427.0 MHz Att=23.00 dB
Mute=Unmuted Slope:x.x, Cal()
Use the
◄ ►
arrow keys to select the setting to edit, and then use the
▲▼
arrow keys to edit
that setting:
Selection
Setting
Fq
(Rx Frequency) 3625-4200 MHz, in steps of 1.0 or 2.5 MHz.
Att
(Rx Attenuation) 0 to 25 dB, in increments of .25dB.
Mute
(Mute setting) Muted (i.e., Tx off) or Unmuted (i.e., Tx on).
Slope
Manual (0.0 to 1.0, in increments of 0.1) or Calibrated.
Press ENTER when done.
F.3.3.3.3.1.1.3 ODU: FSK-control CSAT (2CSATs CSAT #X)
Configuration LNA
LNA: State=On Calibrate-LNA-Current=N
Current-Window=50% Fault-Logic=Summary
Use the
◄ ►
arrow keys to select the setting to edit, and then use the
▲▼
arrow keys to edit
that setting:
Selection
Setting
State
(LNA State) Off or On. This controls whether or not the CSAT provides LNA
Power via the Receive RF Cable.
Calibrate-LNA-Current
Select YES and press ENTER to calibrate the LNA current for use with the
Current-Window function. (Default is NO.)
Current-Window:
A value from 20% to 50% defines the allowable LNA Current change before
declaring a fault. Select 99% to disable the Current Window function.