beautypg.com

3 optional 48v direct current (dc) power interface – Comtech EF Data CDM-625 User Manual

Page 88

background image

CDM-625 Advanced Satellite Modem

Revision 15

Rear Panel Connectors and Pinouts

MN-CDM625

3–18

o Use the slot to pry the holder outward from the IEC power module.

o Pull the holder straight out, and then swing the holder away from the module.

Then, remove and replace the T4A (4 Amp) fuses as needed.


CAUTION – FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES

WITH THE CORRECT TYPE AND RATING.

Finally, reseat the fuse holder in the IEC power module.

3.3.3 Optional 48V Direct Current (DC) Power Interface

This DC input design supersedes the configuration featured on modems built prior

to May 2009.

Figure 3-10. CDM-625 Optional DC Chassis (CEFD P/N PL/12587-2)

Feature

Description

1

On / Off Switch

2

Power Terminal Block

3

Screw-in Fuse Holders / Receptacles

DC Power Specifications

Input Power

48 watts (typical with TPC/LDPC Codec and CnC

module installed), 68 watts (max)
280 watts (typical TPC/LDPC Codec, CnC module

and 48 volt BUC supply installed), 300 watts (max)

Input Voltage

43 – 60 VDC Nominal

36 – 60 VDC Maximum

Connector Type Terminal Block

Fuse Protection

(2X) 5mm x 20mm Slow-blow type fuses:

Modem Fuse: 3Amp/250Volts

BUC Fuse: 6.3 Amp/250 Volts