CDM-625 Advanced Satellite Modem

Revision 15

Front Panel Operation

MN-CDM625

5–23

TPC/LDPC Codec is installed.

3.

The VFEC and ULL encoding selections display only when the optional

VersaFEC Codec is installed.

On the bottom line – When Reed-Solomon is selectable, use the

▲▼

arrow keys to select On or

Off, and then press ENTER.

CONFIG: Rx FEC Reed-Solomon On

Reed-Solomon Decoding =IESS-310(219/201)

(Standard(126/110),IESS-310(219/201)) ()

Use the

▲▼

arrow keys to select an available parameter, and then press ENTER. Depending on

the Framing mode, possible selections are as follows:

IESS-310, open or closed network

219/201

IBS or D&I

126/112

EDMAC or EDMAC2, closed network 200/180
IDR, open network

225/205, 219/201 or 194/178

ESC++ or D&I++, closed network

126/112

Unframed closed network:

○ Comtech standard 220/200

○ Legacy EF Data 225/205, with V.35 scrambling

Otherwise, when Diff Encoder is selectable, use the

▲▼

arrow keys to select On or Off, and

then press ENTER.

CONFIG: Rx FEC Diff Encoder On

When selecting Differential Decoding as OFF, there is no way for the modem to

resolve the phase ambiguities associated with PSK modulations. For BPSK there is a

1 in 2 chance that the polarity of the data will be correct. In QPSK there is a 1 in 4

chance that the data will be correct.

Enc=None (None,Vit,Seq,TCM,TPC,LDPC,VFEC)

Diff Encoder=On (Off,On)

()