beautypg.com

Comtech EF Data CDM-625 User Manual

Page 502

background image

CDM-625 Advanced Satellite Modem

Revision 15

Appendix D

MN-CDM625

D–38

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to

Query

BERT 10E-3

Error Insert

BKE=

1 byte, value of

0 or 1

Command or Query.

Inserts 10E-3 BER in the form x, where:

x = 0 (Off) or 1 (On)
Example: BKE=1

BKE=

BKE?

BKE#

BKE?

BKE=x

(see Description of

Arguments)

BERT Restart

Monitor

BRM=

None

Command only.
Example: BRM=
Note: This command takes no arguments.

BRM=

N/A

N/A

BERT Result

in bit errors

N/A

7 bytes,

numeric

Query only.

BERT monitor results in bit errors. If bit errors exceed 9999999, then BRE=9999999.

N/A

BRE?

BRE=xxxxxxx

BERT Result

in average

BER

N/A

6 bytes

Query only

Returns the value of the average BER in the form a.b x 10-c. First 3 bytes are the value. Byte 5 is the

exponent. Last byte is the indicator of Sync Loss. A ‘*’ in last byte means there was a loss of pattern

synchronization since last restart, but now is synchronized. A ‘_’ (space) in last byte means pattern

synchronization is achieved.
Returns 999999 if there’s no sync in BERT monitor.
Example 1: BRR=2.8E7 (BER is 2.8 x 10

-7

, and in sync)

Example 2: BRR=3.4E5* (BER is 3.4 x 10

-5

, and there was a Sync Loss)

N/A

BRR?

BRR=a.bEcx

ACM

parameters

ACM=

4 bytes

Command or Query.

Defines ACM operating parameters in the form mMAT, where:

m=Minimum ModCod, range is 0 to 9, and A (for ModCod=10) or B (for ModeCod=11)

M=Maximum ModCod, range is 0 to 9, and A (for ModCod=10) or B (for ModeCod=11)

A= Defines action on remote demod unlock (0=go to minimum Tx ModCod, 1=maintain Tx ModCod)

T=Target Eb/No Margin, from 0 to 9 that is two times of the Eb/No in dB (from 0.0dB to 4.5dB).

Example: ACM=0B12

(Sets min ModCod=0, max ModCod=11, maintain Tx ModCod when remote demod unlocks,

sets Target Eb/No at 1.0dB.)

ACM=

ACM?

ACM#

ACM?

ACM=mMAT

(see Description of

Arguments)

Forced

Reboot

FRB=

None

Command only.

Force a hard reset of the unit in 5 seconds.

FRB=

FRB?

FRB*

FRB#

N/A

N/A

Carrier ID

CAI=

1 byte, value

of 0 thru 1

Command or Query.

Carrier ID Enable/Disable in the form x, where:

0 = Disabled

1 = Enabled

CAI=

CAI?

CAI *

CAI #

CAI?

CAI =x

(see Description of

Arguments)