D.5.6 modem information – Comtech EF Data CDM-625 User Manual
Page 511

CDM-625 Advanced Satellite Modem
Revision 15
Appendix D
MN-CDM625
D–47
D.5.6
Modem Information
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to
Query
Hardware
Revision
N/A
4 bytes
Query only.
Unit returns hardware revision level of both main circuit cards, in the form xx.y, where:
xx indicates the main (bottom) card;
y indicates the top (modem) card.
N/A
HRV?
HRV=xx.y
(see Description of
Arguments)
Software
Revision
N/A
5 bytes
Query only.
Unit returns the value of the internal software revision installed in the unit, in the form of x.x.x
Example: SWR=2.0.2
N/A
SWR?
SWR=x.x.x
(see description
of arguments)
Firmware
Information
N/A
256 bytes
Query only.
Unit returns firmware information.
B requests boot code information
Example: FRW=Boot: FW/12865-1-,1.1.1,04/01/07
Otherwise, FRW returns firmware information for Image 1 or 2:
Example: FRW=1
FW/12864-,1.1.1,04/01/07
FW/12866-,1.1.1,04/01/07
FW/12867-,1.1.1,04/01/07
FW/12868-,1.1.1,04/01/07
FW/12875-,1.1.1,04/01/07
FW/12874-,1.1.1,04/01/07
N/A
FRW?B
FRW?1
FRW?2
FRW=xxx…xxx
(see Description of
Arguments)
Serial Number N/A
9 bytes
Query only.
Indicates the modem 9-digit serial number.
Example: SNO=176500143
N/A
SNO?
SNO=xxxxxxxxx
(see Description of
Arguments)
Fractional CnC
90-day
Counter
N/A
7 bytes
Query Only.
Returns the number of seconds that Fractional CnC license has been used in 1 year period since the last
time the CnC counter was reset to 0.
Example: FCC=0000455 (indicating 455 seconds)
N/A
FCC?
FCC=xxxxxxx
(see Description of
Arguments)
Modem
Operational
Full Year
Counter
N/A
8 bytes
Query Only.
Returns the number of seconds that the unit has been powered on since last reset of the counter.
The counter resets to 0 when it reaches 31536000 seconds (seconds in 365 days).
Example: FCF=00001342 (indicating 1342 seconds)
N/A
FCF?
FCF=xxxxxxxx
(see Description of
Arguments)
Software
Revision 2
N/A
38 bytes
Query only.
Unit returns the value of the internal software revision installed in the unit,
Example: SW2=Boot:2.1.1 Bulk1*:2.1.2 Bulk2 :2.1.1
The current active image is indicated with an asterisk.
N/A
SW2?
SW2=x
(see Description