Comtech EF Data CDM-625 User Manual
Page 637

CDM-625 Advanced Satellite Modem
Revision 15
Appendix F
MN-CDM625
F–19
This screen is read-only. Press ENTER or CLEAR to return to the previous menu.
F.3.3.3.3.1.3.2 ODU: FSK-control CSAT (2CSATs CSAT #X) Alarms
Stored-Alarms
As stored events are compiled, the screen shows:
Reading Stored Faults..... Please Wait
Once the events are compiled, the Stored Alarms screen appears as shown here:
Stored Alarms: Clear-All: No (No,Yes)
IF #84: 10/14/04 12:52:08 Power On
Use the
◄ ►
arrow keys to select between the log entries and the Clear-All option.
To view a log entry: With the cursor on the entry number, use the
▲▼
arrow keys to view
through the entries. Up to 99 entries are stored. Each entry provides the following information:
Item
Comments
Entry type
•
IF = Information
•
FT = Fault
•
OK = Fault cleared
Entry number
00 through 99
Date
European Day-Month-Year (DD-MM-YY) format
Time
Hour:Minute:Second (HH:MM:SS) format
Description of information / fault
Example: Power On
To clear the Stored Alarms Log, use the
◄ ►
arrow keys to select Clear-All, and then use the
▲▼
arrow keys to select Yes. Press ENTER to clear the log.
F.3.3.3.3.1.4 ODU: FSK-control CSAT (2CSATs CSAT #X) Info
Info:
Model Tx Rx Misc LNA
()
These read-only screens provide the ODU’s current configuration information without risking
inadvertent changes.
Use the
◄ ►
arrow keys to select Model, Tx, Rx, Misc, or LNA, and then press ENTER.