CDM-625 Advanced Satellite Modem

Revision 15

Appendix F

MN-CDM625

F–19

This screen is read-only. Press ENTER or CLEAR to return to the previous menu.

F.3.3.3.3.1.3.2 ODU: FSK-control CSAT (2CSATs CSAT #X) Alarms

Stored-Alarms

As stored events are compiled, the screen shows:

Reading Stored Faults..... Please Wait

Once the events are compiled, the Stored Alarms screen appears as shown here:

Stored Alarms: Clear-All: No (No,Yes)

IF #84: 10/14/04 12:52:08 Power On

Use the

◄ ►

arrow keys to select between the log entries and the Clear-All option.

To view a log entry: With the cursor on the entry number, use the

▲▼

arrow keys to view

through the entries. Up to 99 entries are stored. Each entry provides the following information:

Item

Comments

Entry type

IF = Information

FT = Fault

OK = Fault cleared

Entry number

00 through 99

Date

European Day-Month-Year (DD-MM-YY) format

Time

Hour:Minute:Second (HH:MM:SS) format

Description of information / fault

Example: Power On

To clear the Stored Alarms Log, use the

◄ ►

arrow keys to select Clear-All, and then use the

▲▼

arrow keys to select Yes. Press ENTER to clear the log.

F.3.3.3.3.1.4 ODU: FSK-control CSAT (2CSATs CSAT #X) Info

Info:

Model Tx Rx Misc LNA

()

These read-only screens provide the ODU’s current configuration information without risking

inadvertent changes.

Use the

◄ ►

arrow keys to select Model, Tx, Rx, Misc, or LNA, and then press ENTER.