beautypg.com

Comtech EF Data CDM-625 User Manual

Page 478

background image

CDM-625 Advanced Satellite Modem

Revision 15

Appendix D

MN-CDM625

D–14

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to

Query

Tx

Data Invert

TDI=

Exception –

600/L

Emulation:

ITD=

1 byte, 0 or 1 Command or Query.

Invert Transmit Data

0=Normal

1=Inverted

Example: TDI = 1 (selects TX Data Invert)
Exception – In 600/L Emulation Mode, instruction is ITD.

TDI=

TDI?

TDI*

TDI#

TDI?

Exception –

600/L Emulation:

ITD?

TDI=x

(see Description of

Arguments)

Tx

Reed-

Solomon

Encoding

TRS=

1 byte, value

of 0 thru 3

Command or Query.

Tx RS encoding

0=Normal (based on the Open Network framing selected)

1=IESS-310 mode, valid with QDI, unframed, IBS, D&I, IDR.

2=EF Data legacy standard (225,205) – unframed, QDI only

3=IBS (126,112) – unframed only

Example: TRS=0 (This is a ‘don’t care’ if no RS is selected under FEC Type)

Available all framing modes, except EDMAC.

TRS=

TRS?

TRS*

TRS#

TRS?

TRS=x

(see Description of

Arguments)

Tx Spectrum

Invert

TSI=

1 byte, 0 or 1 Command or Query.

Tx Spectrum Invert selection, where:

0=Normal

1=Tx Spectrum Inverted

Example:TSI=0 (selects normal)

TSI=

TSI?

TSI*

TSI#

TSI?

TSI=x

(see Description of

Arguments)

Tx Scrambler TSC=

1 byte, 0, 1 or

2

Command or Query.

Tx Scrambler state, where:

0=Off

1=Normal

2=IESS-315

Note: When CnC mode is ON, Tx Scrambler state is fixed as IESS-315.
Example: TSC=1 (Scrambler On)

TSC=

TSC?

TSC*

TSC#

TSC?

TSC=x

(see Description of

Arguments)

Tx Power

Level

TPL=

4 bytes

Command or Query.

Tx Output power level between 0 and -40 dBm (minus sign assumed) for 950 to 1950MHz range.

Tx Output power level between 0 and -25 dBm (minus sign assumed) for 50 to 180MHz range.
Example: TPL=13.4
In AUPC mode, command is not valid. Response will be TPL*.
When APC is active, query returns “TPL=99.9”; when command is not valid, response will be TPL*.
When the external 20 dB attenuator is activated (via AUP), the permitted power level range shifted down by

20dB.
Example: –65 and -20 dBm.
600 Emulation:

Level range: 0 to -20 dBm (minus sign assumed).

600L Emulation:

Level range: 0 to -45 dBm (minus sign assumed).

TPL=

TPL?

TPL*

TPL#

TPL?

TPL=xx.x

(see Description of

Arguments)