beautypg.com

3 info: mode, 4 info: tx, 5 info: rx – Comtech EF Data CDM-625 User Manual

Page 177

background image

CDM-625 Advanced Satellite Modem

Revision 15

Front Panel Operation

MN-CDM625

5–77

5.2.4.3 Info: Mode

Info: Mode: Tx= G.703B:D&I (B8ZS)

Rx= G.703B:IBS (B8ZS)

An example of a Mode Info screen is shown here.

5.2.4.4 Info: Tx

Tx:On 0070.0000MHz PWR=-20.0 TSI=N

Vit+RS:220/200 00064.000 QPSK 7/8 Scrm

An example of the Tx Info screen is shown here. It displays the following information:

Item

Configuration Setting

Top line

Tx Carrier

On, Off, or RTI.

Tx Frequency

xxxx.xxxx MHz.

Power

Power Level (dBm).

TSI

TSI = Tx Spectral Inversion, I=Inverted (on), N=Not inverted (off).

Bottom

line

Encoder

FEC type: Viterbi, TCM, Vit+RS, TCM+RS, TPC, LDPC, VFEC, or

None:DE-xxx (DE is the Differential Encoder setting, shown as DE-Off or DE-

On).

Data Rate

xxxxx.xxx kbps (an asterisk * indicates that the data sense is inverted).

Modulation

BPSK, QPSK, OQPSK, 8-PSK, 8-QAM, 16-QAM.

FEC Rate

1/2, 2/3, 3/4, 7/8, 0.95, 5/16, 21/44 or 1/1.

Scrambler

Scrm, None, or IESS (Turbo Only).

5.2.4.5 Info: Rx

Rx:0070.0000MHz 02.0dB +-30 RSI=N

Vit+RS:126/112 01544.000 QPSK 1/2 Scrm

An example of the Rx Info screen is shown here. It displays the following information:

Item

Configuration Setting

Top line

Rx Frequency

xxxx.xxxx MHz.

Eb/No

12.3 dB (Alarm Point).

Sweep Range

Up to ± 32 kHz.

RSI

RSI = Rx Spectral Inversion, I=Inverted (on), N=Not inverted (off).