9 config: mask ( buc, 10 config: mask ( lnb, 11 config: mask ( cex (g.703 clock extension mask) – Comtech EF Data CDM-625 User Manual
Page 149: 12 config: remote (remote control)

CDM-625 Advanced Satellite Modem
Revision 15
Front Panel Operation
MN-CDM625
5–49
5.2.1.11.9 CONFIG: Mask BUC
Appendix F. CDM-625 ODU (TRANSCEIVER, BUC, LNB) OPERATION
BUC alarm = Active (Active,Mask)
Attach to Tx alarm = No (Yes,No)()
When using L-Band, a Block Up Converter (BUC) may be included in the system. A ‘smart’ BUC
may be monitored and/or controlled via the modem via FSK (Frequency-Shift Keying control).
For a modem in a 1:1 redundancy setup, you must customize the fault indications for the
physical setup.
5.2.1.11.10 CONFIG: Mask LNB
Appendix F. CDM-625 ODU (TRANSCEIVER, BUC, LNB) OPERATION
LNB alarm = Active (Active,Mask)
Attach to Rx alarm = No (Yes,No)()
When using L-Band, a Low-Noise Block Down Converter (LNB) may be included in the system. It
cannot be monitored and/or controlled by the modem, except for the power supply values. For a
modem in a 1:1 redundancy setup, you must customize the fault indications for the physical setup.
5.2.1.11.11 CONFIG: Mask CEX (G.703 Clock Extension mask)
G.703 Clock Extension = Active
(Active, Masked) ()
Use the
▲▼
arrow keys to select Active or Masked, and then press ENTER.
Selecting Active generates a CEX alarm if the G.703 Clock Extension mode is set to TxLock and
the input is lost or removed from the G.703 interface.
5.2.1.12 CONFIG: Remote (Remote Control)
Remote Control=Local
(Local,Serial remote,Ethernet)
()
Use the
▲▼
arrow keys to select Local, Serial remote, or Ethernet, and then press ENTER.