CDM-625 Advanced Satellite Modem

Revision 15

Appendix D

MN-CDM625

D–20

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to

Query

Rx FEC Type RFT=

1 byte, value

of 0 thru 9, A,

B

Command or Query.

Rx FEC Type in the form x, where:

0=None (uncoded) with differential encoding ON

1=Viterbi

2=Viterbi + Reed-Solomon

3= Sequential

4= Sequential + Reed-Solomon

5=TCM (Trellis Code Modulation)

6=TCM + Reed-Solomon

7=TPC (aka Turbo) (Requires Codec, FAST)

8=None (uncoded) with differential encoding OFF

9=LDPC (Requires Codec, FAST)

A=VersaFEC CCM or ACM (Fixed in IP-ACM)

B=VersaFEC ULL

Example: RFT=1 (selects Viterbi only)

RFT=

RFT?

RFT*

RFT#

RFT?

RFT=x

(see Description of

Arguments)

Rx Demod

Type

RMD=

1 byte, value

of 0 to 5

Command or Query (Query only in IP-ACM).

Rx Demodulation in the form x, where:

0=BPSK

1=QPSK

2=OQPSK

3=8-PSK (FAST option)

4=16-QAM (Turbo or Viterbi + RS only)(FAST option)

5=8-QAM (TPC/LDPC only) (Needs Codec + FAST option)

6=Reserved

7=Reserved

8=Reserved

Depending on FEC type, not all of these selections will be valid.

All other codes are invalid.
Example: RMD=2 (selects OQPSK)

RMD=

RMD?

RMD*

RMD#

RMD?

RMD=x

(see Description of

Arguments)