5 select: store/ld (store/load) menus – Comtech EF Data CDM-625 User Manual
Page 180

CDM-625 Advanced Satellite Modem
Revision 15
Front Panel Operation
MN-CDM625
5–80
5.2.5 SELECT: Store/Ld (Store/Load) Menus
Configuration #2: Load Store
()
AVAILABLE
You can store up to 10 modem configurations into an assigned “slot” – 0 through 9. If a
configuration slot is available for storage, the bottom line notes the status of that slot as
AVAILABLE. Otherwise, if the slot contains an existing configuration, the bottom line specifies its
storage time in military format (HH:MM:SS); the date is shown in DAY-MONTH-YEAR format in
accordance with European convention.
To load (recall) a configuration setting:
•
First, use the
◄ ►
arrow keys to move the cursor to the configuration slot number
(
Configuration #X
) and then use the
▲▼
arrow keys to select a slot number from 0 to
9.
•
Next, use the
◄ ►
arrow keys to select Load, and press ENTER when done. Modem
operation then updates as per the configuration settings stored in this slot.
To store (save) a configuration setting:
•
First, make any desired configuration changes to the modem.
•
Next, use the
◄ ►
arrow keys to move the cursor to the configuration slot number
(
Configuration #X
) and then use the
▲▼
arrow keys to select a slot number from 0 to
9.
•
Finally, use the
◄ ►
arrow keys to select Store, and press ENTER when done.
Once a modem configuration is stored into the designated slot, the time and date are recorded,
and this information appears on the bottom line.
Store Override – When storing into a configuration slot that previously had information saved
into the working memory, you are required to confirm the request, as the existing information
will be overwritten:
Configuration #2. Override? No (Y,N) ()
14:06:37 26/10/12
Use the
▲▼
arrow keys to select the Override choice (Y or N), and then press ENTER.