Chapter 3 - Product application Setup

64

Figure 3-18: CAN Switchbox

input Status module (iSm)

when using an input Status module (iSm) instead of a CaN Boom Switchbox, the
system uses existing boom switches in the cab. the system must contain a Switch
Function module (SFm) and a switch (Part # 78-00028) connected to the iSm
to engage and disengage auto boom capabilities. existing wiring from the in-cab
boom switches to the boom valves needs to be disconnected, and this function
assumed by the SFm.

Figure 3-19: ISM

For automatic section control using existing switches, use the following switch
settings:

auto Boom engage/disengage Switch set to “engage”

master Switch oN

active boom switches oN