Calculating the prime value

uS:

( line diameter in inches/ 2 )2 x 3.1416 x line length in inches x 0.5541 = volume in fluid ounces

metric:

(line diameter in cm/2)2 x 3.1416 x line length in cm = volume in ml

units

available units are based on application and drive types (Liquid, granular, Seeder,
Nh3, motor, and injection). the Control Basis determines whether the units avail-
able are area-based, time-based, or distance-based. these parameters should
be established prior to selecting the units of measurement.

to access the Control Basis page from the Units page, press the Settings softkey.
the operator will then be able to scroll through the various options available using
the Arrow keys based on previously-selected application and drive type settings.
once the appropriate units have been established, press the Forward Arrow soft-
key to save the selection and advance to the next page.

Figure 2-26: Units - Control Basis Options

Forward Arrow

softkey (F6)

Settings softkey

(F2)

Arrow keys

Note: most applications are area-based.