Legacy 6000

98-05053 R2

29

Figure 2-23: Servo Settings

Table 2-9: Servo Settings

settings

description

gain

Speed at which the Control Channel reacts to an off-target condition. decrease to slow

down the reaction; increase to speed up reaction (settings too high can result in oscilla-

tion).

Start up drive

drive level used to open valve only from full closed position. increase if valve opens too

slowly and decrease if valve opens too quickly.

master Switch

Control valve response to all booms (oFF). master hold - Control valve will hold in the

same position. Closed - Control valve will drive full closed.

implement Status

Control valve response to when the implement Status switch is open (oFF). hold - Con-

trol valve will hold in same position. Closed - Control valve will drive full closed.

Valve delay

delay in resuming control after turning booms oN from hoLd. when the control valve is

set to close, this feature is deactivated. when master oN, valve will delay control for the

set value.

Valve Location

Location of the control valve in the plumbing (in-Line or Bypass). Combination in-line/

bypass valves like the autorange valve and most hydraulic servos use the in-line setting.

Figure 2-24: PWM Settings