beautypg.com

Appendix c - nh3 application, Nh3 application cal, Density for nh3 and actual n – TeeJet Legacy 6000 Manual User Manual

Page 158

background image

Legacy 6000

98-05053 R2

153

aPPeNdiX C - Nh3 aPPLiCatioN

when using Nh3 mode, review the following settings to ensure the Cal # and
density have been correctly entered. the Cal # is located in Channel Setup under
“Primary Sensor, tools”. the density value is accessed from the ARM Launcher
page in Product Setup.

Nh3 application Cal#

For all Nh3 applications, the Cal # units should be entered in

pulses / gallon. the

Cal # units

dO nOT change even if the displayed units are in (LBS of Nh3 / acre)

or (LBS actual N / acre).

density for Nh3 and actual N

density determines the units of applied and displayed rate (lbs of Nh3 / acre or lbs
of actual N / acre) during application. if application and display rate in lbs of Nh3 /
acre is desired, enter a density of lbs of Nh3 / gal. if application and display rate in
lbs of actual N / acre is desired, enter a density of lbs of actual N / gal.

NOTE:

Temperature affects the Density. The following chart provides a cor-
rected value. Use the temperature or tank pressure column to deter-
mine the correct density.

Example: The display of pounds of actual N / acre is desired. If the temperature

is 65

o

F, the density would be entered during Product Setup as 4.19 lbs

of actual N / per gal.

Nh3 is 82% actual N by weight

1gal Nh3 @ 60oF = 5.15lbs x .82 =
4.22lbs of actual N / 1 gal of Nh3