beautypg.com

Table 2-10: pwm settings – TeeJet Legacy 6000 Manual User Manual

Page 35

background image

Chapter 2 - System overview

30

Table 2-10: PWM Settings

settings

description

gain

Speed at which channel reacts to an off-target condition. decrease to slow down the reaction;

increase to speed up reaction (settings too high can result in oscillation).

Frequency

Frequency of the Pwm valve drive signal (frequency typically recommended by valve or

motor supplier).

minimum duty Cycle

Minimum duty cycle to which the valve will respond, specified by the manufacturer.

maximum duty Cycle

Maximum duty cycle to which the valve will respond, specified by the manufacturer.

Ramp time

time taken for the control to ramp from minimum duty cycle to maximum. decrease if the

valve reacts too slowly when off target. increase if control reacts too quickly (overshooting

target rate).

dither

Prevents valve from sticking (specified by the manufacturer).

master Switch

Control valve response to all booms (oFF). hold - Control valve will hold in the same position.

Closed - Control valve will drive full closed and start backup at minimum duty cycle. Resume

- Control valve will close when booms are turned off but will resume at last used duty cycle

setting when booms are turned on again.

implement Status

Control valve response when implement status is open (oFF).

hold - Control valve will hold in the same position. Closed - Control valve will drive full closed.

Resume - Control valve will close when booms are turned off, but will resume at last used

duty cycle setting when booms are turned on again.

Valve delay

Control delay after turning booms oN from hold/Resume. when the control valve is set to

close, this feature is deactivated. when master oN, the valve will delay control for the set

value.

Figure 2-25: Injection Settings

Table 2-11: Injection Settings

settings

description

Prime Volume

Amount of liquid required to prime the pump. This is the volume necessary to fill

plumbing lines from the chemical tank to the injection point.