beautypg.com

Rate control mode – TeeJet Legacy 6000 Manual User Manual

Page 139

background image

Chapter 7 - eXt

134

to view messages such as area applied and ground speed. if “off” is selected, a
lightbar is not required to collect data.

Table 7-1: Guidance Only Mode and Log Data Mode Settings

setup name

setting

description

Controller

during Controller Setup, a controller driver name must be set to “None” to run

in guidance only mode.

guidance only

Lightbar

text/Lights

if the lightbar is set to “text/Lights”, machine guidance can be used. data is

logged to the PC Card (refer to Lightbar Setup for additional information).

Log data mode with a lightbar

Lightbar

text only

if the lightbar is set to “text only”, guidance cannot be used. where applied

data is logged to the PC Card.

Log data mode without a lightbar

Lightbar

off

if the lightbar is set to “off”, guidance cannot be used. where applied data is

logged to the PC Card. a lightbar is not required.

Rate CoNtRoL mode

Rate Control mode implies that an external rate controller is connected to one of
the Com ports on the Legacy 6000 console. during Rate Control mode, several
options exist where data can be collected with or without guidance. if rate data is
being collected without guidance, the use of a lightbar is optional. all data collected
during Rate Control mode is considered “as applied” data.

To configure Rate Control mode, the controller setting must be set to the type
of rate controller connected to the Legacy 6000 console. if this setting is set to
“None”, product application will not be possible.

Table 7-2: Rate Control Mode Settings

setup name

setting

description

Controller

a driver Name

during Controller Setup, a controller driver name must be selected to perform

product application.

Rate Control with guidance

Lightbar

text/Lights

if the lightbar is set to “text/Lights”, machine guidance can be used. data is

logged to the PC Card (refer to Lightbar Setup for additional information).

Log data mode with a lightbar and without guidance

Lightbar

text only

if the lightbar is set to “text only”, guidance cannot be used. as applied data

is logged to the PC Card.