Ac/dc power supply (cont.) – Rockwell Automation 7000A PowerFlex Medium Voltage Drive (A-Frame) - Classic Control User Manual
Page 378
6-74
Component Definition and Maintenance
7000A-UM150F-EN-P –June 2013
7000 “A” Frame
Terminal / Connections Descriptions
The terminal connections are shown in Figure 6.
59
.
Control signals
DC outputs
Single phase input
TOP
VIEW
FRONT
VIEW
Earth
Line
Neutral
Figure 6.59 – Terminal locations on AC/DC power supply
P1-AC input
PIN#
LABEL
1
EARTH
2
LINE
3
NEUTRAL
P2-DC output
PIN#
LABEL
1
+56V
2
+56V COMM
3
+56V
4
+56V COMM
P3-FAIL output
PIN#
LABEL
3
DC POWER FAIL (OUTPUT POWER GOOD)
14
AC/DC FAIL COMM (LOGIC RETURN)
15
CURRENT SHARING
16
AC POWER FAIL (POWER FAIL)
Ensure the output of the supply is 56V DC.
There is a potentiometer on the top of the power supply that adjusts the 56
Volt DC output for the power supply. Isolate the output of the power
supplies; multiple supplies in series will affect your measurements. With the
control power on and the output of the AC/DC Converter isolated from the
drive control, adjust the potentiometer until the output equals 56 volts DC.
Perform this test on each power supply. When all adjustments are complete,
re-connect the power supply to the circuit and re-measure the output. Adjust
if necessary.
If it is not possible to maintain 56 V DC, the power supply may be faulty.
AC/DC Power Supply
(cont.)