beautypg.com

Rockwell Automation 7000A PowerFlex Medium Voltage Drive (A-Frame) - Classic Control User Manual

Page 326

background image

6-22

Component Definition and Maintenance

7000A-UM150F-EN-P –June 2013

7000 “A” Frame

8. Disconnect the plug that connects the thermal sensor to the circuit

board.

9. Remove the screw that attaches the thermal sensor to the heatsink.

10. Replace with the new thermal sensor and cable assembly.

11. Note there is a small voltage difference between the thermal sensor

and its heatsink. For proper function, it is essential to mount the small
insulating pad between the thermal sensor and the heatsink and the
insulating bushing between the thermal sensor mounting screw and
the thermal sensor (see Figure 6.20).

12. Replacement of the heatsink with the new thermal sensor is in the

reverse order of removal.

13. Follow procedure “Uniform Clamping Pressure” to ensure the

heatsinks are clamped to a uniform pressure.


Insulating bushing

Mounting pad

Temperature feedfack

circuit board

Mounting screw

Thermal sensor

and cable assembly

Figure 6.20 – Replacing the Heat Sensor