Rockwell Automation 57C570 AutoMax PC3000 User Manual User Manual
Page 91

5Ć13
Step 9.
In the Edit Input/Output Range dialog box, change the
range to the next available Input/Output range by using
the Value list box. Make sure there are no device conflicts.
Step 10. Save your changes by clicking OK; exit the PC3000
Properties dialog box by clicking OK.
Step 11. When prompted by the Creating a Forced Configuration
dialog box, click Yes.
Step 12. Close the System Properties and Control Panel.
5.8.3
Adding the PC3000 Processor Card's Address to
the SYSTEM.INI File
You must edit the SYSTEM.INI file, located in the directory where
Windows 95 is installed, to add a reference to the PC3000 Processor
card.
Step 1.
Using a text editor, open the SYSTEM.INI file that is
located in the directory where Windows 95 is installed.
Step 2.
Locate the section [386Enh].
Step 3.
Add this additional line to the [386Enh] section:
EMMExclude=MEM1-MEM2
.
Where:
MEM1 = the beginning address of the next
PC3000 Processor card
MEM2 = the ending address of the next
PC3000 Processor card
Example
: EMMExclude=CA00-CBFF
NOTE: Although Windows 95 displays the address range in
five digits, you must enter the address as four digits. Do not
enter the fifth digit in the SYSTEM.INI file.
Step 4.
Add a comment to this address that documents the serial
number of the Processor card. For example:
EMMExclude = CA00-CBFF //(serial number)
Step 5.
Save and close the SYSTEM.INI file.