beautypg.com

Rockwell Automation 57C570 AutoMax PC3000 User Manual User Manual

Page 53

background image

3Ć15

Figure 3.7 shows an IBMĆcompatible personal computer containing

an AutoMax PC Link Interface module (M/N 57C445) connected to a

StandĆAlone Transceiver. A twistedĆpairĆtoĆcoax balun (AMP 555053Ć1

is recommended) is used to convert the cable between the PC Link

module and the transceiver. The balun is connected to the PC Link

module via the BNC Tee Adapter (M/N 45C70). Note that a 75 ohm

terminating load (M/N 45C71) is required. The balun is connected to

the transceiver using twistedĆpair wire.

1

2 3

4

5

6

7 8

9 10 P/S

PC3000 Network Interface

AutoMax Rack

Drop Cable (M/N 57C366)

Hub (Rack/Power

TwistedĆ

Pair Wire

FiberĆOptic Cable

StandĆAlone Transceiver

(M/N 57C365)

Drop Cable

(M/N 57C366)

AutoMax

Rack

Network Communications

Module

Supply M/N 57C368

containing 10

transceivers

M/N 57C367)

Master

Slave

Personal Computer Containing

PC Link Interface Module

Balun

TwistedĆPair Wire

Tee Adapter

. . .

Terminating

Load

Coax

Cable

(M/N 45C71)

Figure 3.7 Ć Connecting a Personal Computer to a StandĆAlone Transceiver