FĆ2
Getting Started
You can find the sample configurations and programs for the AutoMax PC3000
on the application disk for the AutoMax Programming Executive software V4.1.
To copy the templates into a system in the Executive software, do the following:
Step 1.
Obtain the application disk, and determine if it is writeĆprotected. If it
is, move the tab on the disk to unĆprotected.
Step 2.
Place the disk in the drive, and run the AutoMax Programming
Executive software.
Step 3.
In the System Configurator, choose Copy from the System menu.
Step 4.
Select the drive containing the application disk, and select the system
PC3000.
Using the Sample Configurations
Once you have the sample configurations copied into a system, you can begin
to view and customize them for your application. The DCSĆNET network
interface and the AĆB remote I/O scanner interface each store the sample
configurations. You can view the assigned variables by using the Variable
Configurator for the selected interface module." Just doubleĆclick the selected
module" for the AutoMax PC3000 displayed in the Rack Configurator. Detailed
variable descriptions document the purpose of the assigned variables.
Use this table to help you locate the configuration you want:
БББББББ
Б
БББББ
Б
БББББББ
Sample
configuration:
ББББББББ
Б
ББББББ
Б
ББББББББ
Location:
БББББББББ
Б
БББББББ
Б
БББББББББ
Description:
БББББББ
БББББББ
DCSĆNET network
master
ББББББББ
ББББББББ
DCSĆNET network
interface, Drop Area 1
БББББББББ
БББББББББ
Generic register assignments for
drop 1 of the DCSĆNET network.
БББББББ
Б
БББББ
Б
Б
БББББ
Б
Б
БББББ
Б
Б
БББББ
Б
БББББББ
FlexPak 3000 DC drive
basic configuration
ББББББББ
Б
ББББББ
Б
Б
ББББББ
Б
Б
ББББББ
Б
Б
ББББББ
Б
ББББББББ
DCSĆNET network
interface, Drop Area 6
БББББББББ
Б
БББББББ
Б
Б
БББББББ
Б
Б
БББББББ
Б
Б
БББББББ
Б
БББББББББ
Variables that configure the
FlexPak 3000 drive have been
defined for the registers in drop
6. Some individual bits have also
been assigned variable names.
You can copy this configuration
to other drops as necessary per
your application.
БББББББ
Б
БББББ
Б
Б
БББББ
Б
Б
БББББ
Б
Б
БББББ
Б
БББББББ
GV3000 AC drive
basic configuration
ББББББББ
Б
ББББББ
Б
Б
ББББББ
Б
Б
ББББББ
Б
Б
ББББББ
Б
ББББББББ
DCSĆNET network
interface, Drop Area 8
БББББББББ
Б
БББББББ
Б
Б
БББББББ
Б
Б
БББББББ
Б
Б
БББББББ
Б
БББББББББ
Variables that configure the
GV3000 drive have been defined
for the registers in drop 8. Some
individual bits have also been
assigned variable names.
You can copy this configuration
to other drops as necessary per
your application.
БББББББ
Б
БББББ
Б
Б
БББББ
Б
БББББББ
1794 (Flex) I/O
definitions
ББББББББ
Б
ББББББ
Б
Б
ББББББ
Б
ББББББББ
AĆB Remote I/O scanner
interface,
Input/Output registers for
Racks 1 and 2
БББББББББ
Б
БББББББ
Б
Б
БББББББ
Б
БББББББББ
Registers in these racks are
allotted for 16Ćbit input and
output 1794 I/O modules.
БББББББ
Б
БББББ
Б
Б
БББББ
Б
БББББББ
1791 (Block) I/O
definitions
ББББББББ
Б
ББББББ
Б
Б
ББББББ
Б
ББББББББ
AĆB Remote I/O scanner
interface,
Input/Output registers for
Rack 3 and 4
БББББББББ
Б
БББББББ
Б
Б
БББББББ
Б
БББББББББ
Registers in these racks are
allotted for 16Ćbit input and
output 1791 I/O modules.