Kinetix 6200 and Kinetix 6500 Connector Data
Figure 37 - Peak Inverter Overload (T
PK
< 2.0 s)
(1) Base current (I
Base
) and peak current (I
PK
) are a percentage of the continuous drive current rating (I
Cont
).
Figure 38 - Peak Inverter Overload (T
PK
< 2.0 s)
(1) Base current (I
Base
) and peak current (I
PK
) are a percentage of the continuous drive current rating (I
Cont
).
% Base Current (I /I )
0%
60%
100%
50%
45%
40%
35%
30%
25%
20%
15%
10%
5%
0%
80%
20%
40%
I = 150%
I = 200%
I = 250%
Legend
Maximum D
uty C
ycle (D )
max
Cont
PK
PK
PK
(1)
Base
Applies to these Bulletin 2094 power
modules:
2094-BC01-MP5-M, 2094-BMP5-M,
2094-BC01-M01-M, 2094-BM01-M,
2094-BC02-M02-M, 2094-BM02-M,
2094-BC04-M03-M, 2094-BM03-M
% Base Current (I /I )
0%
60%
100%
50%
45%
40%
35%
30%
25%
20%
15%
10%
5%
0%
80%
20%
40%
Legend
Maximum D
uty C
ycle (D )
max
Cont
PK
PK
(1)
Base
I = 150%
I = 200%
Applies to these Bulletin 2094 power
modules:
2094-BC07-M05-M, 2094-BM05-M