Wire the input power (ipd) connector – Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual
Page 106
106
Rockwell Automation Publication 2094-UM002E-EN-P - May 2012
Chapter 5
Connecting the Kinetix 6200 and Kinetix 6500 Drive System
Wire the Input Power (IPD) Connector
This example applies to any IAM module or common-bus leader IAM power
module.
Figure 55 - IAM Power Module (IPD connector)
Table 53 - Input Power (IPD) Connections
Table 54 - Termination Specifications
ATTENTION: Make sure the input power connections are correct when wiring
the IPD connector plug and that the plug is fully engaged in the module
connector. Incorrect wiring/polarity or loose wiring can cause explosion or
damage to equipment.
DC-
DC+
L3
L2
L1
1 2 3 4 5 6
Bulletin 2094
IAM Power Module, Top View
OPL Connector (LIM module
(1)
) or Other Three-phase Input
(1) The Bulletin 2094 power modules are compatible with only the 2094-BL02, 2094-BLxxS, and 2094-XL75-Cx LIM modules.
IPD Connector
(IAM or leader IAM module)
2094-AL09
LIM Module
2094-ALxxS, 2094-BLxxS, or
2094-XL75S-Cx LIM Modules
OPL Pin
Signal
OPL Pin
Signal
IPD Pin
Signal
1
L1’
4
L1’
6
L1
2
L2’
3
L2’
5
L2
3
L3’
2
L3’
4
L3
4
1
3
N/A
2
DC+
1
DC-
IAM Module Cat. No.
Input VAC
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
2094-BC01-Mxx-M
2094-BC02-M02-M
460V AC
2.5 (14)
10 (0.38)
1.2…1.5
(10.6…13.2)
2094-BC04-M03-M
6 (10)
16 (0.63)
2.4…3.0
(21.6…26.5)
2094-BC07-M05-M
30 (3)