21. Calculate additional bus capacitance, if this applies to your application,
and enter the value here (version 18.00 or later), or refer to Appendix D on
to set the Add Bus Cap parameter.
The Additional Bus Capacitance field only applies to the IAM power
module.
22. Click OK.
23. Repeat
step 1
through
step 18
for each 2094-EN02D-M01-S
x control
module.
IMPORTANT
When configured to use the Bulletin 1394 or 2094 shunt modules, the
IAM bus regulator capacity attribute displays the utilization of total
shunt power available (as a percent) based on the power rail
configuration.
Refer to Kinetix Motion Accessories Specifications Technical Data,
publication
, for more information.
IMPORTANT
DC common-bus applications must calculate Total Bus Capacitance and
Additional Bus Capacitance and set the Add Bus Cap parameter in the
leader IAM power module. However, you can set the parameter as
shown in
or by using RSLogix 5000 software as shown in
Refer to Appendix C beginning on
, for more information on
making the calculations. Refer to Appendix D beginning on
for more information on setting the Add Bus Cap parameter.