Troubleshooting the Kinetix 6200 and Kinetix 6500 Drive System
Chapter 8
for a description of the messages that scroll across
the display during powerup.
Table 79 - Four-character Display Messages
Drive Condition
Display String
Priority
Maximum
Number of
Messages
Displayed
Auxiliary Feedback Not
Configured as Feedback
Only
Auxiliary Feedback Configured as
Feedback Only
Axis 1
Axis 1
Axis 2
IP Address Display
(1)
IP = xxx.xxx.xxx.xxx
1
2
Sercos Node Address Display
(2)
Sercos NODE = xx
1
2
Safety Signature ID
(3)
SAFETY SIGNATURE = xxxxxxx
Firmware Upgrade
FIRMWARE UPDATE
2
2
Decelerating to a Stop as a Result of a Fault
ABORTING
Refer to footnote
(4)
Initialization Fault - Std. and Fault Code
(5)
INIT FLT Sxx
X1:INIT FLT Sxx
X2:INIT FLT Sxx
3
4
(6)
Initialization Fault - Mfg. and Fault Code
(5)
INIT FLT Mxx
X1:INIT FLT Mxx
X2:INIT FLT Mxx
Safety Fault
(5)
SAFE FLT xx
Refer to footnote
(4)
Node Fault
(5)
NODE FLT xx
Refer to footnote
(4)
Major Fault - Std. and Fault Code
(5)
FLT Sxx
X1:FLT Sxx
X2:FLT Sxx
Major Fault - Mfg. and Fault Code
(5)
FLT Mxx
X1:FLT Mxx
X2:FLT Mxx
Minor Fault - Std. and Fault Code
(5)
FLT Sxx
X1:FLT Sxx
X2:FLT Sxx
4
3
(7)
Minor Fault - Mfg. and Fault Code
(5)
FLT Mxx
X1:FLT Mxx
X2:FLT Mxx
Inhibit - Std. and Fault Code
(5)
INHIBIT Sxx
Refer to footnote
(4)
5
2
Inhibit Fault - Mfg. and Fault Code
(5)
INHIBIT Mxx
Refer to footnote
(4)
Safe Limited Speed
SAFE LIMITED SPEED
Refer to footnote
(4)
6
10
Power-up
(8)
‘BOOT’…’INIT’…’LOAD’…’DONE’…’BOOT’…’INIT’…’DONE’…‘LOAD’…’TEST’…FW Version: X.XXX
Waiting for CIP connection
STANDBY
Connecting
CONNECTING
Configuring Drive Attributes
CONFIGURING
Synchronizing
(1)
SYNCING
Waiting for DC-bus Up
PRE-CHARGE
Drive has been Shutdown
SHUTDOWN
Refer to footnote
(4)
Drive Axis has Stopped
STOPPED
Refer to footnote
(9)
Drive is Starting
STARTING
Refer to footnote
(4)
Drive is Running
RUNNING
Refer to footnote
(4)
Drive is Executing a Test Procedure
TESTING
Refer to footnote
(4)
Decelerating to a Stop as a Result of a Disable
STOPPING
Refer to footnote
(4)
Alarm Fault - Standard Fault Code
(5)
ALARM Sxx
X1:ALARM Sxx
X2:ALARM Sxx
Alarm Fault - Mfg. Specific Fault Code
(5)
ALARM Mxx
X1:ALARM Mxx
X2:ALARM Mxx
Node Alarm
NODE ALARM xx
Refer to footnote
(4)
(1) Applies to only 2094-EN02D-M01-Sx EtherNet/IP control modules.
(2) Applies to only 2094-SE02F-M00-Sx sercos control modules.
(3) Applies to only 2094-xx02x-M0x-S1 (safe-speed monitoring) control modules.
(4) Condition not supported by auxiliary feedback-only axis.
(5) A short descriptive string follows the displayed code.
(6) One node fault, two initialization, safety, major, or minor faults for axis 1, and one initialization, major, or minor fault for axis 2.
(7) One node fault, one initialization, safety, major, or minor faults for axis 1, and one initialization, major, or minor fault for axis 2.
(8) Text in single quotation marks, ‘BOOT‘ for example, is shown one word at a time (not scrolled).
(9) Condition not displayed.