2 option specifications, 1 paper feeder unit (with scanner) pf-705, Option specifications -5 – Konica Minolta bizhub PRESS C8000e User Manual
Page 411: Paper feeder unit (with scanner) pf-705 -5
bizhub PRESS C8000
11-5
11.2
Option Specifications
11
11.2
Option Specifications
d
Reference
For options other than Paper Feeder Unit (with scanner) PF-705, ADF, and Dehumidifier Heater HT-506,
see Section 13 in User’s Guide - Main Body.
11.2.1
Paper Feeder Unit (with scanner) PF-705
ISO standard sizes are used for B series by default. For ISO/JIS switching, please contact your service rep-
resentative.
Foolscap refers to 8 × 13
w, 8.12 × 13.2 w, 8.25 × 13 w, or 8.5 × 13 w.
Name
PF-705
Function
Feed paper into main body
Configuration
3 paper trays
Paper tray capacity
4,630 sheets (80 g/m
2
)
Trays 4, 5: 1,390 sheets
Trays 6: 1,850 sheets
Paper size
Standard: SRA3
w, A3 w, B4 w, A4 w/v, SRA4 w/v,
B5
w/v, A5 w/v, B6 w, A6 w, 13 × 19 w, 12 × 18 w,
11 × 17
w, 8.5 × 11 v, 5.5 × 8.5 v
Custom: max. 330 mm × 487 mm to min. 100 mm × 140 mm
Detectable standard sizes can be switched as follows:
•
(A4
w and A5 w) or (8.5 × 11 w and 5.5 × 8.5 w)
•
(SRA4
w and A5 v), 8.5 × 14 w, or Foolscap
•
8.5 × 11
v or 9 × 11 v
Other than the above mentioned, the following standard siz-
es can be switched when the machine is set to use JIS sizes,
and also to use K sizes in the Administrator Setting provided
on the Utility Menu Screen.
•
B5
v or 16K v
Paper type
Fine/Plain/Color Specific: 64 g/m
2
to 350 g/m
2
Coated GL/ML/GO/MO: 81 g/m
2
to 350 g/m
2
Thin Coated: 81 g/m
2
to 105 g/m
2
Use Dehumidifier Heater HT-506 at a humidity of 50% or
more.
Tab paper (with orientation specified, simplex only)
Labels and OHP transparencies are unavailable.
Reverse delivery: 64 g/m
2
to 300 g/m
2
Duplex delivery: 64 g/m
2
to 300 g/m
2
Paper weight
64 g/m
2
to 350 g/m
2
Dimensions
996 (W) × 772 (D) × 1,208 (H) mm
Weight
Approx. 242 kg
Power source/requirements
DC: 5 V, 12 V, –12 V (24 V supplied from internal DC)
AC1 (supplied from main body, for heater): 180 to 264 V
(50/60 Hz)
AC2 (supplied from outlet, for HT and DC): 230 V ± 10%
(50/60 Hz)
Power consumption
DC: 270 W or less
AC: 580 W or less