Konica Minolta bizhub PRESS C8000e User Manual
Page 364

bizhub PRESS C8000
10-56
10.9
[03 Administrator Setting] - [01 System Setting]
10
1
Follow the procedure on page 10-2 to display the Administrator Setting Menu Screen.
2
Press [01 System Setting], [05 Expert Adjustment], [07 Quality Adjustment], and [03 Printer Gamma
Sensor Adj.] in sequence.
The Printer Gamma Sensor Adjustment Screen will be displayed.
3
Select the screen to be adjusted.
% The screens provided here are the same as those provided in the Printer Gamma Offset Adjustment.
% To clear the colorimetric data currently set on the machine and restore the factory default data,
press [Reset Adj. data]. Press [Yes] on the dialog. Or, press [No] to cancel resetting the data.
4
Press [Print Mode].
The Print Mode Screen will be displayed.
5
Select A4
v paper tray, then press Start on the control panel.
A test pattern will be output, and the Printer Gamma Sensor Adjustment Screen will be restored auto-
matically.
6
Place the test pattern on the original glass.
% Position the test pattern [1] face down, with green arrow [2] pointing at the left side.
% Carefully align the test pattern [1] to the vertical original size guide [3] and horizontal original size
guide [4] on the original glass.
% Place about 10 sheets of blank copy paper on top of the test pattern [1].
% Close the ADF.