beautypg.com

Allied Telesis AlliedView-EMS 4.0.2 Device-Manager User Manual

Page 412

background image


AlliedView™-EMS 4.0.2 Device Management Guide

Page 412 of 441

Note

- The value of the Port Speed parameter of a port with an established link

automatically changes to '10Mbps' when the value of its Port Mode parameter is

changed from 'auto' to 'manual'.

Note

- The current firmware version does not allow the Port Ingress Rate Limit and

Port Egress Rate Limit parameters to be configured.

Note

- AT-CV5M01: The current firmware version does not allow Port Speed and

Port Duplex Status parameters to be set to '1Gbps' and 'unknown' values

respectively.

AT-CM70S

4 x TI/E1 + 10/100TX over SFP-based fiber.

LED

State

Description

DUP

Green

Orange

The port is operating in full-duplex mode.

The port is operating in half-duplex mode.

LT

Green

Link Test is enabled

OAMB

Green

OAM Bypass is enabled

OAMV

Green

OAM Visible is enabled

LCDS

Green

Line Card Dip Switch is enabled

Note

- The current firmware version will not allow remote port connection on the RJ-45

port if the SFP port is set to disabled.

Note

- The Module Name parameter always displays 'yyyyyyyy' as its default value when not

yet configured.