beautypg.com

Allied Telesis AlliedView-EMS 4.0.2 Device-Manager User Manual

Page 405

background image


AlliedView™-EMS 4.0.2 Device Management Guide

Page 405 of 441

Note

- AT-CV5M01: The value of the Port Mode and Port Duplex Status parameters

automatically changes to 'manual' and 'half duplex' respectively when the value of its

Port Speed parameter is changed from '100Mbps' to '10Mbps'.

Note

- AT-CV5M01: The current firmware version does not allow Device Manager

to display the TX port values configured via Telnet.

Note

- AT-CV5M01: The current firmware version does not allow Port Mode, Port

Duplex Status and Port MDIX parameters to be configured if the current Port Speed

parameter is set to '100Mbps'.


Port Statistics

Displays the basic port statistics configuration information. Options to view all/per

module information are displayed.


Remote Line Card Info

Displays the Remote Line Card information of the AT-CMxx series line cards.


Remote Module Info

Displays the module info of the line cards.

Note

- AT-CV5M01: The current firmware version does not allow the Remote Local

Module Name parameter to be configured.

Note

- The current firmware version does not allow the Remote Module Name

parameter to be configured.

Note

- AT-CV5M01: The current firmware version does not display the Remote

Module Name, Remote Module Type and Remote Module Software Version

parameters correctly.

Note

- AT-CV5M01: The current firmware version returns a 'noSuchName' value for

the Remote Module Software Version parameter.


Remote Port Info

Displays the remote port information of the line cards.

Note

- AT-CV5M01: The current firmware version returns a 'noSuchName' value for

the Remote Port MDIX and Remote Port Flow Control parameters.

Note

- AT-CV5M01: The current firmware version does not allow Remote Port

Mode, Remote Port Duplex and Remote Port Speed parameters of TX type of ports

to be configured. Attempting to configure these parameters other than its current

values will result in the error message: "The error occurred with 'Set' operation.

Error: time out occurred."