Utilization
Displays the port's utilization information.
Interface Info
Standard
Displays high-capacity port statistics including received and transmitted
unicast/multicast/broadcast packets on the port, link up/down trap and port speed.
Note
- The following parameters are not applicable to the AT-x600 series and should
be ignored:
•
Specific Media MIB
•
Received Non Unicast Packets
•
Transmitted Non Unicast Packets
•
Transmitted Buffer Length
Note
- Device Manager will not display the correct state of the ports and duplex
LEDs if logged-on in SNMPv3 mode using a user account with no read access to the
Interface Info parameters.
Additional
Info
Displays port statistics such as the number of frames received and transmitted on
the port, bytes received and transmitted on the port, and port status.
Note
- The current firmware version returns a 'noSuchName' value for the following
parameters:
•
Received Bytes (HC)
•
Received Unicast Packets (HC)
•
Received Multicast Packets (HC)
•
Received Broadcast Packets (HC)
•
Transmitted Bytes (HC)
•
Transmitted Unicast Packets (HC)
•
Transmitted Multicast Packets (HC)
•
Transmitted Broadcast Packets (HC)
Note
- The Promiscuous Mode parameter is implemented as 'read-only'.
Note
- The Counter Discontinuity Time parameter is not applicable to the AT-x600
series and should be ignored.
Note
- Valid MIB Set values for the Port Alias parameter is up to 64 characters.
Attempting to enter values greater than the valid range will be accepted but values
exceeding 64 characters will be truncated.
Error
Statistics
Displays error statistics.