Security menu – Allied Telesis AlliedView-EMS 4.0.2 Device-Manager User Manual
Page 210

AlliedView™-EMS 4.0.2 Device Management Guide
Page 210 of 441
Note
- Valid MIB Set values for the Data Pattern parameter should range from 1 to
4294967295. However, the current firmware version does not allow Device
Manager to display the correct value greater than 2147483647. Attempting to enter
values greater than 2147483647 will cause the new value to be converted to the
following values:
•
4286578688 - 4294934527: 8388608 - 16744447
•
4294934528 - 4294967167: 32768 - 65407
•
4294967168 - 4294967295: 128 - 255
Note
- Device Manager does not handle objects of type OCTET STRING correctly.
As a result, the Address parameter will not be configurable and will display a
sequence of bytes in hexadecimal format instead of the actual destination of ping
packets.
Ping Statistics
Displays statistics of the Ping polling.
Security Menu
From the Security menu, you can view and edit port access entity information such as the
PAE port information and the Supplicant PAE information.
Port-based Authentication
Authentication
Status
Displays the status of the port-based authentication.
PAE Port Info
Standard
Displays standard PAE port information.
Note
- Device Manager does not handle objects of type BITS correctly. As a
result, the Capabilities parameter will display an 8-bit binary string instead of
the actual PAE functionality supported. However, the PAE functionality
supported can still be determined by looking at the bits that are on from
right to left:
•
Bit 0 - Authenticator
•
Bit 1 - Supplicant
Enterprise
Displays enterprise PAE port information.
Authenticator PAE Info
Standard
Displays standard authenticator PAE information.