Allied Telesis AlliedView-EMS 4.0.2 Device-Manager User Manual
Page 255

AlliedView™-EMS 4.0.2 Device Management Guide
Page 255 of 441
Note
- The current firmware version returns '???(0)' for the Configuration Action
parameter.
Note
- AT-9408LC/SP: The current firmware version does not allow the
Configuration Action parameter to be configured.
Access Lists
Displays management access lists for the switch.
Note
- Device Manager does not handle objects of type BITS correctly. As a result,
the Application parameter may display any of the following values:
•
00100000 - ping
•
01000000 - web
•
10000000 - telnet
•
11100000 - all
but may not be configured.
Note
- The current firmware version does not allow the Device Manager to display
the option 'All' for the Application parameter.
Note
- L3 Models: The current firmware version does not return any Set Error when
configuring the Row Status parameter to 'not in service'.
Date and Time
Displays and configures the current date and time of the device.
MAC Address Table
Displays a list of static MAC addresses configured on the switch.
Note
- The MIB (atiStackSwitch.mib - L2+ Models: v2.36 / L3 Models: v3.13)
supported by the current firmware version defines the Module ID, Port ID and Port
List parameters as "read-write". As a result, Device Manager displays these
parameters as configurable objects. However, attempting to configure these
parameters will show that the firmware does not accept any value.
Note
- The only valid MIB Set value for the Status parameter is 'destroy'. Attempting
to set this parameter to any other value may result in the value being ignored or the
error message: "The error occurred with 'Set' operation. Error: bad value."
Note
- L3 Models: The current firmware version does not return any Set Error when
configuring the Status parameter to 'not in service'.
Reset
Resets the switch.
Telnet
Starts a Telnet connection to the switch.