beautypg.com

Allied Telesis AlliedView-EMS 4.0.2 Device-Manager User Manual

Page 315

background image


AlliedView™-EMS 4.0.2 Device Management Guide

Page 315 of 441

Note

- Device Manager does not handle objects of type OCTET STRING

correctly. As a result, the Address parameter will display a sequence of bytes

in hexadecimal format instead of the actual IP address of the device.

Note

- The current firmware version does not allow the Port Number and

Assignment Type parameters to be configured.

Note

- The current firmware version allows the user to enter up to 128

characters for the Label parameter but truncates entered values to 127

characters.

Note

- Configuring Prefix Length parameter will result in the error message

"The error occurred with 'Set' operation. Error: time out occurred."

However, the new value is still set successfully.


Route

Number

Displays the IP routing number on the switch.


Route

Table

Displays the IP routing table on the switch.

Note

- The current firmware version returns the value 'NULL' for the Routing

Protocol MIB parameter.

Note

- The following parameters are implemented as 'read-only':

Destination Port Number

Routing Type

Routing Protocol MIB

Next Hop AS Number

Destination Metric 1

Destination Metric 2

Destination Metric 3

Destination Metric 4

Destination Metric 5

Row Status

IP

Statistics

Displays statistics about IP, such as the number of IP datagrams received.

Note

- Valid MIB Set values for the Default TTL parameter should range from 1-255.

However, the current firmware version does not allow this parameter to be set to

'1' as its value. Attempting to set this parameter to '1' will result in the error

message "The error occurred with 'Set' operation: time out occurred." Connection

with the device will be lost and the only way to re-establish connection will be to

perform a manual reset.