Allied Telesis AlliedView-EMS 4.0.2 Device-Manager User Manual
Page 315

AlliedView™-EMS 4.0.2 Device Management Guide
Page 315 of 441
Note
- Device Manager does not handle objects of type OCTET STRING
correctly. As a result, the Address parameter will display a sequence of bytes
in hexadecimal format instead of the actual IP address of the device.
Note
- The current firmware version does not allow the Port Number and
Assignment Type parameters to be configured.
Note
- The current firmware version allows the user to enter up to 128
characters for the Label parameter but truncates entered values to 127
characters.
Note
- Configuring Prefix Length parameter will result in the error message
"The error occurred with 'Set' operation. Error: time out occurred."
However, the new value is still set successfully.
Route
Number
Displays the IP routing number on the switch.
Route
Table
Displays the IP routing table on the switch.
Note
- The current firmware version returns the value 'NULL' for the Routing
Protocol MIB parameter.
Note
- The following parameters are implemented as 'read-only':
•
Destination Port Number
•
Routing Type
•
Routing Protocol MIB
•
Next Hop AS Number
•
Destination Metric 1
•
Destination Metric 2
•
Destination Metric 3
•
Destination Metric 4
•
Destination Metric 5
•
Row Status
IP
Statistics
Displays statistics about IP, such as the number of IP datagrams received.
Note
- Valid MIB Set values for the Default TTL parameter should range from 1-255.
However, the current firmware version does not allow this parameter to be set to
'1' as its value. Attempting to set this parameter to '1' will result in the error
message "The error occurred with 'Set' operation: time out occurred." Connection
with the device will be lost and the only way to re-establish connection will be to
perform a manual reset.