Allied Telesis AlliedView-EMS 4.0.2 Device-Manager User Manual
Page 377
AlliedView™-EMS 4.0.2 Device Management Guide
Page 377 of 441
Note
- The current firmware version does not allow the Port parameter to be
configured.
Additional
Info
Displays additional information on the port's spanning tree parameters.
Note
- The current firmware version does not allow the Protocol Migration
parameter to be set to 'true'.
Note
- The current firmware version does not allow the Point-to-Point Config
parameter to be set to 'auto'.
Note
- Valid MIB Set values for the Port Path Cost Config parameter is [1-
200000000] inclusive. However, the current firmware version allows the user to set
this parameter to '0' as its value and will automatically set the entered value to valid
values.
MAC Control Pause
Displays information about the MAC Control Pause function on a single ethernet-
like interface.
Note
- The current firmware version returns a 'noSuchName' value for the Received
Frames (HC) and Transmit Frames (HC) parameters.
Note
- The PAUSE Config parameter is implemented as 'read-only'.
MAU Info
Displays interface-related MAU information for the port.
Note
- The MAU Status and Default MAU Type parameters are implemented as
'read-only'.
Note
- The MAU Type List parameter is not applicable to the AT-x900-24X series
(AlliedWare Plus) and should be ignored.
Note
- The Mau Type List Bits and HC False Carriers parameters are not applicable
to the AT-x900-24X series (AlliedWare Plus) and should be ignored.
Note
- The current firmware version returns the value 'NULL' for the MAU Type
and Default MAU Type parameters.
MAU Negotiation Info
Displays the MAU's auto-negotiation settings and its status.
Note
- The Administration Status and Restart parameters are implemented as 'read-
only'.