Page 358 of 441

Port Trunking

Aggregator Port LIst

Displays Link Aggregation Control information for every Aggregation Port

associated with this device.

Note

- Valid MIB Set values for the Actor System Priority and Actor Port Priority

parameters are in the range [0..65535] inclusive.

Note

- The following parameters are implemented as 'read-only':

Actor Operational Key

Partner Administrative System Priority

Partner Administrative System ID

Partner Administrative Key

Partner Administrative Port

Partner Administrative Port Priority

Actor Administrative Status

Partner Administrative Status

LACP Statistics

Displays Link Aggregation information for every port that is associated with this

device.


LACP Debug

Displays Link Aggregation debug information for every port that is associated with

this device.


Enable

Enables the port.


Disable

Disables the port.