beautypg.com

Allied Telesis AT-9000 Series User Manual

Page 161

background image

AlliedWare Plus Version 2.1.8 Management Software Web Interface User’s Guide

161

Figure 56. Modify Port PoE Settings Page

4. Change the following settings as needed:

Interface— Indicates the ID of the port you are modifying. You
cannot change this parameter.

PoE port status— Select Enabled or Disabled to enable or
disable PoE on this port.

PoE device Description— Enter the description of the PoE device
that is connected to the port. The description can contain up to 256
alphanumeric characters. Spaces and special characters are
allowed.

Note

Only the first 16 characters of the description will be displayed.

PoE Port Power Limit— Enter the power limit, in milliwatts (mW),
that the switch provides to the device connected to the port. The
range is 4000 to 30000 mW.