beautypg.com

Fru operational tests – HP StoreEver ESL G3 Tape Libraries User Manual

Page 149

background image

Test progress is shown in the Verification Tests window.

11.

After the test is complete, click Reports to view the test results.

For more information about how to work with graphical reports, see

“Verification test graphical

reports” (page 154)

.

For information about how to interpret test logs, see

“Verification test logs” (page 157)

.

For information about how to email, print, or save text logs, see

“Emailing, saving, and printing

test logs” (page 160)

.

FRU operational tests

There are two ways to run the FRU operational tests. You can select the FRU test from the Verification
Tests window, or if that FRU is supported by the verification tests you can run the test from the
Events window. This section explains both procedures.

The screens displayed by the FRU operational tests vary, depending on which sub-test is selected.
For example, if you click Picker Assembly, I/E Assembly, or Drive Sled Assembly, and click Start,
the Select Scratch Tapes window appears.

Running tests from the Verification Tests window

To run FRU operational tests from the Verification Tests window:

1.

Log on as an administrator.

2.

Ensure that you are viewing the physical library. From the View menu or in the Managed
Views area of the LMC, select the name of the physical library.

3.

Select Tools

→Library Diagnostics→Verification Tests.

The Verification Tests window appears.

FRU tests are available for the Accessor Assembly, Picker Assembly, Drive Sled Assembly, I/E
Assembly, and Scan Barcode. You can only test one FRU at a time.

The following steps provide instructions for running the Scan Barcode test. The other tests
provide similar windows and functionality for the other FRUs.

4.

From the Select Test drop-down list, click FRU.

5.

From the Select Sub-test drop-down list, click Scan Barcode.

6.

Click Start.

7.

If prompted to take the library offline, click Yes.

The Attention Select an Element dialog box appears. This dialog box enables you to enter
any coordinate address in the library (aisle, module, rack, section, column, and row). The
address does not need to be occupied by a drive or cartridge.

8.

Click Finish.

Test progress is shown in the Verification Tests window in the Test Results area of the screen.

Working with verification tests

149