8. Messages
608
maintenance contract for HDLM. For details on the
DLMgetras
utility, see
7.2 The DLMgetras Utility for Collecting HDLM Error Information.
1025
Details
A parameter value is invalid.
Action
Refresh the host information, and then perform the operation again. If the same
error occurs again, execute the DLMgetras utility for collecting HDLM error
information, and then contact your HDLM vendor or maintenance company if
you have a maintenance contract for HDLM. For details on the
DLMgetras
utility, see 7.2 The DLMgetras Utility for Collecting HDLM Error Information.
1026
Details
The acquisition of path information has been aborted, because the path
configuration was changed while the system was attempting to acquire the path
information.
Action
Refresh the host information, check the path status, and then perform the
operation again.
1027
Details
The error monitoring interval and the number of times that the error needs to
occur are conflicting with the automatic failback-checking interval.
Action
Set the intermittent error-monitoring interval to a value that is equal to or greater
than (automatic-failback-checking-interval x
number-of-times-error-is-to-occur-for-intermittent-error-monitoring).
1028
Details
An attempt to recover the path failed because an error occurred in the path.
Action
Resolve the error in the relevant path, and then re-execute.
1029
Details