HP Hitachi Dynamic Link Manager Software User Manual
Page 406

6. Command Reference
384
monitoring interval and the number of times that the error is to occur:
-intvl
error-monitoring-interval
Specify the monitoring interval for an intermittent error. Use a value from
1
to
1440
minutes. The default is
30
.
During intermittent error monitoring, if changes are made in the settings of
the intermittent error monitoring interval, the error count and the elapsed
time measured since monitoring starts are set to 0, and monitoring starts by
using the new settings.
Outside the duration of intermittent error monitoring, if changes are made in
the settings of the intermittent error monitoring interval, the new settings
take effect after the next time automatic failback succeeds. Outside the
duration of intermittent error monitoring, the number of errors that determine
an intermittent error is not counted and this value is not changed.
The monitoring interval specified in this parameter is stored even though
specifying
-iem
off
disables intermittent error monitoring. Therefore,
when you re-enable intermittent error monitoring and a monitoring interval
is not specified, error monitoring will be performed by using the stored
monitoring interval.
-iemnum
number-of-times-error-is-to-occur
Specify the number of times the error is to occur. Valid values are from 1 to
99. The default is
3
.
During intermittent error monitoring, if you change the number of times that
the error is to occur, the error count and the elapsed time measured since
monitoring starts are reset to 0, and monitoring starts by using the new
settings.
Outside the duration of intermittent error monitoring, if you change the
number of times that the error is to occur, the new settings take effect after
the next time automatic failback succeeds. When intermittent error
monitoring is not being performed, the number of errors that determine that
an intermittent error has occurred is not counted and this value is not
changed.
The number of times that the error is to occur is stored in the system, even
when
-iem off
is specified and intermittent error monitoring is disabled.
Therefore, when you re-enable intermittent error monitoring without
specifying the number of times, the error monitoring will be executed using
the value stored in the system.
When the
set
-iem
on
operation is executed during error monitoring, even
though you do not change the conditions for intermittent error, the number of
errors and the time elapsed since the error monitoring starts are reset to 0.