8. Messages
494
Re-install HDLM.
KAPL01076-I
The permanent license has been installed.
Details
You need not install a license because a permanent license has already been
installed.
Action
None.
KAPL01078-W
The operation terminated because the path configuration changed
during execution of the HDLM command. Operation name = aa...aa
Details
aa...aa:
monitor
Action
After the dynamic reconfiguration of the HDLM device has finished, re-execute
the HDLM command.
KAPL01079-W
The intermittent error monitoring function cannot be set up
because automatic failback is disabled.
Details
The intermittent error monitoring function cannot be set up because automatic
failbacks are disabled.
Action
Enable automatic failbacks, and then re-execute.
KAPL01080-W
The error monitoring interval and the number of times that the
error is to occur conflict with the automatic failback checking
interval.
Details
An intermittent error cannot be detected by using the values specified for the
following: the checking interval for automatic failbacks, the error-monitoring
interval, and the number of times the error needs to occur.
Action
Set the intermittent error-monitoring interval to a value that is equal to or greater
than (automatic-failback-checking-interval x