HP Hitachi Dynamic Link Manager Software User Manual
Page 518

8. Messages
496
aa...aa:
/var/tmp/hdlm_license
Action
If a license key file exists, delete it.
/var/tmp/hdlm_license
KAPL01088-W
The specified parameter values cannot be specified at the same
time. Operation name =
aa...aa
, parameter =
bb...bb
, parameter values
=
cc...cc
Details
aa...aa:
view
bb...bb: Parameter name
cc...cc: Parameter values that cannot be specified at the same time
Action
Execute
help
operation-name of the HDLM command (
dlnkmgr
) to check
which parameter can be specified, and then retry. For details on the
help
operation, see 6.3 help (Displays the Operation Format).
KAPL01089-E
One of the following was executed at the same time as an HDLM
command set -lic operation: another set -lic operation, or an
update of the license for an update installation.
Action
Check the license by using the HDLM command's
view
-sys
-lic
operation. If
necessary, re-execute the HDLM command's
set
-lic
operation. If the same
error message is output again, contact your HDLM vendor or the maintenance
company if there is a maintenance contract for HDLM.
Do not perform the following operations:
• Simultaneously execute the HDLM command's
set
-lic
operation with the
view -sys -lic
operation.
• Execute the HDLM command's
set
-lic
operation while the license for an
upgrade or re-installation is being updated.
KAPL01090-E
The Offline path cannot be placed Online because a path error
occurred. path ID =
aa...aa
, details =
bb...bb
Details
An attempt to recover the path failed because an error occurred in the path.