beautypg.com

1 format, 2 parameters – HP Hitachi Dynamic Link Manager Software User Manual

Page 460

background image

7. Utility Reference

438

7.2 The DLMgetras Utility for Collecting HDLM Error Information

This utility collects information that is needed to analyze HDLM errors that have

occurred: information such as error logs, integrated trace files, trace files, definition

files, core files, system crash dump files, and libraries. The collected information is

archived in a file and saved to the directory that you specified. The following files are

output:

Name-of-the-directory-containing-a-system-crash-dump-file/

system-crash-dump-file
This file is a symbolic link file to a system crash dump file.

hbsa.tar.Z

This file contains compressed error information of the Hitachi Command Suite

products other than HDLM. This file is output only when using the Hitachi

Command Suite product that is the target for collecting error information.

getras.tar.Z

This file contains compressed HDLM information and system information.

For details on the information that is stored in each file, see 7.2.3 List of Collected

Error Information.
When you want to collect information other than that in 7.2.3 List of Collected Error

Information, define the information to collect in a file for defining the information to

be collected. Information defined in a file for defining the information to be collected

is compressed into

getras.tar.Z.

When the host is restarted, a part of the information that was collected by the

DLMgetras

utility will be cleared. If an error occurs, immediately execute this utility.

7.2.1 Format

/opt/DynamicLinkManager/bin/DLMgetras

{

directory-to-which-collected-information-is-output

[-f

name-of-a-file-for-defining-the-information-to-be-collected

]|-h}

You can also use lower-case characters (

dlmgetras

) as follows:

/opt/DynamicLinkManager/bin/dlmgetras

{

directory-to-which-collected-information-is-output

[-f

name-of-a-file-for-defining-the-information-to-be-collected

]|-h}

7.2.2 Parameters

directory-to-which-collected-information-is-output