HP Hitachi Dynamic Link Manager Software User Manual
Page 408
![background image](/manuals/397694/408/background.png)
6. Command Reference
386
Legend:
AFB: Automatic failback
IEM: Intermittent error monitoring
#1
When this condition is not satisfied, the KAPL01080-W message is output and an
error occurs. The status of intermittent error monitoring does not change.
#2
Because automatic failback is
off
,
intermittent error monitoring is disabled.
Example
The following example shows how to monitor for intermittent errors.
Change the IEM settings.
• While a path is being monitored, the value of the
error count and the elapsed monitoring time are
reset to 0, and then intermittent error monitoring
will restart.
#1
• When a path is not being monitored, the IEM
settings will take effect again when the path is
recovered from the error status by performing an
automatic failback.
Set IEM to
off
.
• IEM is disabled.
• The error count, elapsed monitoring time, and
information about paths not subject to automatic
failbacks are cleared.
off
Set AFB to
on
.
The operations of AFB and IEM do not change.
Change the AFB setting.
AFB operates using new settings.
Set AFB to
off
.
AFB is disabled.
Set IEM to
on
.
IEM is enabled.
#1
off
on
#2
Set AFB to
on
.
AFB and IEM are enabled.
#1
Set AFB to
off
.
The operations of AFB and IEM do not change.
off
Set AFB to
on
.
AFB is enabled.
Set AFB to
off
.
The operations of AFB and IEM do not change.
Setting
Executable operation
Result of operation
AFB
IEM