2. HDLM Functions

34

If you want to check whether intermittent error monitoring is being performed for the

path, check the IEP item displayed when the

dlnkmgr

command's

view -path

operation is executed with the

-iem

parameter. If a numerical value of 0 or greater is

displayed in the above items, then intermittent error monitoring is being performed.

Table 2-5: When Effects of a User Changing the Intermittent Error Information

#1

User operation

Number of errors

and time passed

since error
monitoring

started

Information

about paths not

subject to
automatic

failback

Changing the intermittent
error monitoring settings

Turning

off

Reset

Reset

#1

Changing the conditions for an

intermittent error while intermittent
error monitoring is being performed

Reset

#2

Inherited

Turning intermittent error

monitoring

on

by executing the

set

operation, (but not changing the

conditions) while intermittent error

monitoring is being performed

Changing the conditions for an

intermittent error outside the

intermittent error monitoring

(Not applicable) (Not

counted.)

Inherited

Changing the automatic

failback settings

Turning

off

Reset

Reset

Changing the path status

Taking the path

Offline(C)

Reset

Reset

Placing the path

Online

while

intermittent error monitoring is not

being performed

(Not applicable) (Not

counted.)

Reset

Placing the path

Online

while

intermittent error monitoring is

being performed

Inherited

(Not applicable)
If a path has been
removed from the

paths subject to

automatic
monitoring, that

path is no longer

monitored.

Restarting the HDLM manager

Reset

#3

Inherited

Restarting the host

Reset

Reset