4. HDLM Operation
333
Note
The following message might be output to the console window or syslog
while the node is running:
Could not read symbolic link for: /dev/rdsk/
c3t50060E80033A9902d2s2 path not loaded
This message is output when HDLM deletes a logical device file for an sd or
ssd device managed by HDLM. Perform the procedure for updating the
device ID information (steps 17 to 20) so that this message is not output next
time the node starts. For details, refer to the Sun Cluster documentation.
14. Execute the
dlnkmgr
command's
view
operation on all nodes in the cluster, and
display the status of each program.
The following shows an example of executing the command:
# /opt/DynamicLinkManager/bin/dlnkmgr view -sys
HDLM Version :
x
.
x
.
x
-
xx
Service Pack Version :
Load Balance : on(extended lio)
Support Cluster :
Elog Level : 3
Elog File Size (KB) : 9900
Number Of Elog Files : 2
Trace Level : 0
Trace File Size(KB) : 1000
Number Of Trace Files : 4
Path Health Checking : on(30)
Auto Failback : on(1)
Intermittent Error Monitor : off
HDLM Manager Ver WakeupTime
Alive
x.x.x-xx
yyyy
/
mm
/
dd
hh
:
mm
:
ss
HDLM Alert Driver Ver WakeupTime ElogMem Size
Alive
x.x.x-xx
yyyy
/
mm
/
dd
hh
:
mm
:
ss
4096
HDLM Driver Ver WakeupTime
Alive
x.x.x-xx
yyyy
/
mm
/
dd
hh
:
mm
:
ss
License Type Expiration
Permanent -
KAPL01001-I The HDLM command completed normally. Operation
name = view, completion time =
yyyy
/
mm
/
dd
hh
:
mm
:
ss
#