beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 571

background image

8. Messages

549

Action

If the error code is

9001

,

-1

:

You do not have read permissions for the installation information settings

file. Make sure that you have access permissions.

If any other error code is output:

Contact your HDLM vendor or the maintenance company if there is a

maintenance contract for HDLM.

KAPL09218-E

aa...aa

cannot be executed.

Details

A utility or command that

installhdlm

uses was not in the correct location, or

you do not have a required permission.
aa...aa:

installhdlm_analysis

,

dlnkmgr

, or

dlmsetconf

Action

If aa...aa is

dlnkmgr

or

dlmsetconf

:

The correct location of

dlnkmgr

and

dlmsetconf

is

/opt/

DynamicLinkManager/bin

. If

dlnkmgr

or

dlmsetconf

was not in the

correct location, or you did not have a required permission, re-execute

installhdlm

.

If aa...aa is

installhdlm_analysis

:

The correct location of

installhdlm_analysis

is the same directory as

installhdlm

. Make sure that the utility you want to execute is in the

correct location and that you have the required permissions. If a utility is not
in the correct location, copy the required files to the correct location, and

then retry the operation. If you do not have a required permission, grant

required permissions to yourself, and then retry the operation.

KAPL09219-E

An internal error occurred in the installhdlm_analysis. Error
Code =

aa...aa

,

bb...bb

Details

An internal error occurred in the

installhdlm_analysis

.

aa...aa: Error number (decimal number) that specifies the executed processing
bb...bb: Return value (decimal number) of the executed processing

Action

Contact your HDLM vendor or the maintenance company if there is a