Chapter 3: Software Overview

UWBTracer/Trainer User Manual

24

LeCroy Corporation

Record

Start

Causes the Analyzer to begin recording.

Stop

Causes the Analyzer to stop recording.

Reupload

Opens a window that controls partial uploading.

Report

File Information

Displays information about the recording such as the number of frames
and triggering setup.

Error Summary

Displays the Errors report of the Traffic Summary, listing the numbers of
each error type.

Timing Calculations

Calculates timing between two frames.

Traffic Summary

Summarizes the numbers and types of errors, packets, transactions,
split transactions, and transfers that occurred in the open trace.

Device List

Lists the DUTs, active devices, archive devices, and wireless USB in the
Device List window by DUTs, Type, EUI-48, Address, Alias,
Last Updated, and User Notes.

Timing Analysis

Opens the Timing Analysis window with a Beacon Period and/or
WUSB Detail View.

Run Verification
Script

Opens a window to allow you to run verification scripts

over the open trace.

Search

Go to Trigger

Positions the display to show the triggering event at the top.

Go to Frame/

Packet/Transaction/

Transfer

Positions the display to show a specific frame or decode level.

Go to Marker >

Positions the display to the selected marked frame.

Go to >

Positions the display to the specified item.

Find

Allows searches by multiple criteria.

Find Next

Looks for the next instance of an event specified with Goto or Find.

Search Direction

Allows the search direction to be changed from Forward to Backward or
Backward to Forward.

Search Channel

MPI or RF

Menu/Option